Steelco VS 4-12 Series

Steelco has developed a full range of high capacity steam sterilizers for the perfect solution from the smallest facility to the largest central sterilzation supply department. Steelco sterilizers offer: versatility, safety, high performance, with low cost of ownership and traceability.

Steelco sterilizers are engineered to offer best in class solutions for the reduction of energy and water consumption to give users lowest operating costs per load. ECO options: Steelco's range of high end solutions to save water and energy.

Leading in process safety innovation

4D-Sensor4DIR sensor technology is a breakthrough innovation in steam sterilization monitoring. It performs state-of-the-art steam saturation and penetration monitoring by directly measuring sterilant conditions of every load as required by the standards (EN 285:2015, ISO 17665- 1:2006 clause 10.1)!

Discover more How does the 4DIR sensor work.

 

  •  

    7-inches-control-panel
    • User friendly control panel with multi level user access system.
    • Software with 20 programmes, 12 of which are pre-defined and 8 can be customized according to the customer’s needs.
    • Frontal service door realized in one single stainless steel AISI 304 panel.
    • Height adjustable feet enabling an easy floor levelling of the autoclave.
    • Possibility to have the technical area on the left or on the right side of the autoclave.
    • Process piping made of stainless steel AISI 316L with tri-clamp fittings.
    • Double stage vacuum pump.
    • Steam generator equipped with min/max water level indicator.
    • Integrated thermal paper printer.
    • Ergonomic working and loading position.
    • A built in degassing device placed on top of the sterilizer

     

    Test/service programmes: heating, Bowie & Dick, vacuum test, Helix test.
    Working programmes at 121°C and 134°C / 249,8°F and 273,2°F for textiles, instruments, rubbers.
    Process cycle and factory programmed according to EN 285.

    Dimensions and capacity

    Model chamber (mm/inch)

    litres/gal

    autoclave (mm/inch)
    W H D W H D
    Single door version
    VS 4/1 670 / 26.38 700 / 27.56 686 / 27.01 322 / 85.06 1250 / 49.21 1900 / 74.80 992 / 39.06
    VS 6/1 670 / 26.38 700 / 27.56 986 / 38.82 462 / 122.05 1100 / 43.31 1900 / 74.80 1292 / 50.87
    VS 8/1 670 / 26.38 700 / 27.56 1286 / 50.63 603 / 159.30 1100 / 43.31 1900 / 74.80 1592 / 62.68
    VS 10/1 670 / 26.38 700 / 27.56 1586 / 60.87 744 / 196.54 1100 / 43.31 1900 / 74.80 1892 / 74.49
    VS 12/1 670 / 26.38 700 / 27.56 1940 / 76.39 910 / 240.40 1100 / 43.31 1900 / 74.80 2222 / 87.48
    Pass-through version (two doors)
    VS 4/2
    670 / 26.38
    700 / 27.56 710 / 27.95 333 / 87.97 1250 / 49.21 1900 / 74.80 992 / 39.06
    VS 6/2
    670 / 26.38
    700 / 27.56 1010 / 39.76 474 / 125.22 1100 / 43.31 1900 / 74.80 1292 / 50.87
    VS 8/2
    670 / 26.38
    700 / 27.56 1310 / 51.57 614 / 162.20 1100 / 43.31 1900 / 74.80 1592 / 62.68
    VS 10/2
    670 / 26.38
    700 / 27.56 1610 / 63.39 755 / 199.45 1100 / 43.31 1900 / 74.80 1892 / 74.49
    VS 12/2
    670 / 26.38
    700 / 27.56 1940 / 76.39 910 / 240.40 1100 / 43.31 1900 / 74.80 2222 / 87.48

    Standard compliant
    The Steelco sterilizers autoclaves are designed and constructed to comply with the latest guidelines: 93/42/EEC and its revised version, 97/23/EC, EN 285, EN ISO 14971, EN ISO 17665-1, IEC EN 61010-1, IEC EN 61010-2-040, IEC EN 60601-1-6, EN 61326-1.

    Not available for sales USA market.

This website uses cookies to manage authentication and navigation statistics.
By using our website, you agree that we can place these types of cookies on your device.