DS PH Series, Parts and Glassware washers
-
Combination of clamps and welded construction
Extensive documentation is provided on the orbital welding.Washing chamber and sump
All the connections to the washing chamber respect the L/D <3 formula to ensure the cleaning integrity of all surfaces.Exhaust valve
With partial closure to reduce energy loss. With hermetic closure in case of washing toxic substances.Drain valves
Double drain system with single or double total closure with no residual water left.Washing pump
Stainless steel high quality washing pump with drain valve.Drying and filtering
The heating elements enable variable drying temperature control. The ULPA filter is placed in line at the end of the drying path before entering the chamber and rack.Special applications
Customised solutions with special drying programs or HPV (hydrogen peroxide vapor) decontamination according to customer needs. Furthermore, interfacing with isolator, T.O.C. (Total Organic Carbon) water treatment supply, pull out electrical panel configured to different global electrical standards.Compliance and guidelines
The planning and the production of our washing and drying systems is based on standards and guidelines recognized both worldwide as well as in the final installation country: GAMP - cGMP - A.S.M.E. - MCA - ISPE baseline - FDA - 21CFR part 11 - ISO 9001 -